Pump retrofit eliminates EUR 150k annual maintenance cost

22nd June 2022
New pump internals from Sulzer solve reliability issues and improve productivity for chemical processing plant

Correctly matching equipment to the application is essential for reliable and efficient operations. When machines fail to deliver the required performance, they can cause a significant bottleneck in the manufacturing process resulting in an ongoing loss of potential revenue. For a chemical plant in the Netherlands, years of maintenance issues with a group of ammonia pumps had incurred considerable expense and downtime despite repeated interventions from the original equipment manufacturer (OEM). All these issues are now a distant memory after Sulzer delivered a retrofit solution that continues to prove reliable and cost-effective.

As the maintenance group responsible for all assets in the chemical processing plant, Sitech Manufacturing Services has to ensure ongoing productivity and continued operations in a very competitive market. Proactive maintenance schedules and planned upgrades allow the company to deliver reliability and cost-effective production. In a recent project, Sulzer was called in to offer its design expertise and provide a retrofit solution to overhaul three bad actors that continued to present issues that the OEM was unable to resolve.

Counting the cost

Within the vast array of equipment at the processing facility, three pumps, which were originally installed in 1968, are tasked with the onerous job of pumping the ammonia feedstock for the production of nitrogen fertilizer. Two of the between bearing design, type BB3, twin impeller axial flow pumps are powered by steam turbines and one by a fixed-speed electric motor. In addition to this, an extra pump is kept as a spare.

From the outset, the pumps have suffered from poor reliability, with a mean time between failure of around 12 months, which has incurred high maintenance costs for the plant. The engineers had to deal with high vibration, excessive wear and broken impellers, all of which were causing a loss of performance and annual maintenance costs of around EUR 150’000.
Over the years, several design changes and mechanical improvements have been made to the pumps. In 1996, due to the corrosion that was also being experienced, the OEM suggested all the internal components were changed for parts made using Super Duplex stainless steel.

Searching for the solution

However, the material change did not address the inherent design issues, and the pumps continued to suffer from jammed wear rings, damaged impellers and excessive wear. The resultant loss of performance and high maintenance costs continued to cause issues, to the point that the pumps were identified as a major cause for concern in the nitrogen process.
Sulzer became aware of the issues being experienced with the pumps and offered to provide an engineered solution that would deliver long-term performance and reliability. Having appreciated the benefits that Sulzer could deliver, Sitech Manufacturing Services supplied the spare pump to the local service center in the Netherlands as the impeller was broken and the pump needed to be repaired.

The retrofit process was preceded by a root cause analysis to determine the weak points in the existing design, and enabled Sulzer to establish the best solution for this application.

Faultless reliability

The first step was to use a laser scanner to create a precision model of the entire pump. Once this was complete, the design work could start on the new impellers and driveshaft. Sulzer’s high energy pump experts in Leeds, UK, supported the project with their extensive equipment knowledge and application experience.

Starting with Sulzer’s own BBT-D pump design as a reference, the engineers focused on the impeller characteristics as well as the wearing parts, which required improved durability. Once complete, the plans were sent to the manufacturing site for this project in Germany, which created the new impellers and shaft.

Ben Lauwerijssen, Regional Sales Manager, Benelux for Sulzer explains: “Back in the Netherlands, the pump was reassembled with the new components before being tested for performance. Once complete, the pump was returned to the chemical plant where it was installed, commissioned and found to run very smoothly. In all, the whole project was completed in just 20 weeks.”

Having identified these pumps as a source of concern in the manufacturing process, two more pumps were also scheduled for the same improvements and now, only one pump remains to be completed. The retrofits have been a considerable success and the first has now delivered faultless reliability for over six years, confirming that Sulzer could deliver all of the improvements that were promised.

Frank Sleijpen at Sitech Manufacturing Services, concludes: “The continued vibration monitoring has shown that Sulzer’s design modifications have not only greatly improved the MTBF, but readings are significantly lower than those for the original pumps. This is a good indication of continued performance and long-term reliability, which will continue to save the company money year on year.”

 

Image 1: Sitech Manufacturing Services supplied the spare pump to the local service center in the Netherlands

Image 2: From the outset, the pumps have suffered from poor reliability, with a mean time between failure of around 12 months

Image 3: The retrofits have been a considerable success and the first has now delivered faultless reliability for over six years


About Sulzer:

Sulzer is a global leader in fluid engineering. We specialize in pumping, agitation, mixing, separation and application technologies for fluids of all types. Our customers benefit from our commitment to innovation, performance and quality and from our responsive network of 180 world-class production facilities and service centers across the globe. Sulzer has been headquartered in Winterthur, Switzerland, since 1834. In 2021, our 13’800 employees delivered revenues of CHF 3.2 billion. Our shares are traded on the SIX Swiss Exchange (SIX: SUN).

www.sulzer.com


Editorial Contact: Admin

Tel: +44 (0)1905 917477

Web: www.dmaeuropa.com

Email: press-team@dmaeuropa.com

Address: Progress House, Midland Road, Worcester, Worcestershire, WR5 1AQ, United Kingdom

Reader Contact:

Sulzer – EMEA: Simon Aspinall, EMEA Marketing Manager PE & RES

Tel: +44 (0)1132 701244

Web: https://www.sulzer.com

Email: simon.aspinall@sulzer.com

Address: Sulzer Pumps (UK) Ltd. Manor Mill Lane Leeds West Yorkshire LS11 8BR